Tính năng
MiCOM P14x Feeder Management and Overcurrent Protective Relays are especially suitable where a complete or advanced power system protection scheme solution is required. They include Overcurrent, Earth/Ground Fault and complete protection, advanced communication and integrated functions for feeders. MiCOM P14x protection relays also offer function keys for integral scheme control functionality. The following models are available: MiCOM P141 – Feeder management relay MiCOM P142 – Feeder management with integrated Autoreclose MiCOM P143 – Feeder management, integrated Autoreclose and Check Synchronism MiCOM P145 – Feeder management, Autoreclose, Check Synchronism and Enhanced operator control functions Housed in standard MiCOM 40TE, 60TE or 80TE, 4U case sizes, MiCOM relays offers a complete and scalable range of feeder protection, serial and Ethernet communications, including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese. Standard Manufacturer’s Warranty: 2 years Extended Warranty: Up to 10 years (product registration required, applies to Easergy MiCOM, please check with your local representative for availability, some exclusions apply). |
Lợi ích
Advanced Feeder Management Extensive functionality to meet all feeder applications Programmable Scheme Logic to allow easy customization Comprehensive communication options including IEC 61850 and redundant Ethernet ports |
Các ứng dụng
MiCOM P14x Feeder Management protection relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables in Electrical Transmission or Distribution Protective Systems MiCOM P14x range is a suite for all applications where overcurrent protection is required. It is suitable for solidly earthed, impedance earthed, Petersen coil earthed and isolated systems. |
LINK TÀI LIỆU |
MiCOM P14x
Giá : Liên Hệ
Feeder Overcurrent Protection Relays for complete Feeder Management in transmission & distribution. Overcurrent, Earth Fault and complete feeder power system protection, control and monitoring including advanced communication and integrated functions dedicated to feeders. Models available: MiCOM P141, MiCOM P142, MiCOM P143, MiCOM P145
Sản phẩm tương tự
Sepam series 10 offers 3 types of digital overcurrent and earth fault protection devices for feeders and distribution transformers, each one dedicated to a single application. Models available: Sepam 10N, Sepam 10B, Sepam 10A
MiCOM P22x range of protection relays is designed for motor protection applications and includes a complete set of protection functions. Models available: MiCOM P220, MiCOM P225
Modular Substation Computer with Backup Protection. MiCOM C264 is the latest generation of modular substation computers. It provides traditional input/output (I/O) management, communication gateway, measurement center and automation processor. MiCOM C264P also includes backup protection, enabling the use as a truly multifunctional device. Models available: MiCOM C264P
Rơ-le bảo vệ có thể rút kéo cho các ứng dụng trung thế. Rơ-le bảo vệ trung thế tập trung vào sự an toàn và an ninh mạng
Numerical Busbar Protection Relay Scheme. MiCOM P746 numerical busbar protection provides centralized complete protection for all voltages level up to extra high voltage busbar configurations. Models available: MiCOM P746
Generator Protection Relays. MiCOM generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for small, medium and large generators
Sepam series 20 offers 7 types of digital current or voltage protection for standard distribution systems, each one dedicated to a single application. Models available: Sepam S20, S24, T20, T24, M20, B21, B22